1. Core Electrical Equations

Battery Runtime (Hours)

H = (Wh × DoD) ÷ (Dish_W ÷ η + Idle_W)

Where DoD = 0.85 (LiFePO4/Li-Ion) or 0.50 (AGM); η = 0.93 (Direct DC), 0.88 (100W USB-C PD), or 0.78 + 12W tare (AC inverter).

Two-Way DC Loop Drop (Volts)

V_drop = I × (2 × L_ft × R_1000 ÷ 1000)

Uses annealed copper resistance at 20°C: 18 AWG = 6.385 Ω, 16 AWG = 4.016 Ω, 14 AWG = 2.525 Ω, 12 AWG = 1.588 Ω, 10 AWG = 0.999 Ω per 1,000 ft.

2. Starlink Roam Service Boundaries (50GB vs. Unlimited)

While hardware power consumption depends only on physical load and sky obstructions, off-grid travelers should verify current Starlink Roam plan rules before departure:

Plan Tier Data Allowance In-Motion & Pause Rules
Roam 50GB 50 GB/month (per-GB opt-in top-ups available) Supports in-motion use and pause/unpause billing in monthly increments; ideal for weekend overlanders.
Roam Unlimited Unlimited inland data Supports in-motion use, coastal waters, and international travel in available markets (subject to regional stay limits).

3. Primary Sources Log

Parameter Primary Reference Verified Value
Dish Input & Power Starlink Mini Specifications (starlink.com/specifications) 12–48V DC · 60W Max · 25–40W Avg · 15W Idle
Official USB-C Cable Starlink Shop Accessory Specification 5m (16.4 ft) · 100W (20V/5A) USB-C PD Required
Carry-On Lithium Limit FAA / PHMSA 49 CFR 175.10(a)(18) <= 100 Wh (No approval) · 101–160 Wh (Approval, max 2)
DC Wire Resistance NEC Chapter 9 Table 8 / ABYC E-11 Copper Ω/1,000 ft · 3%–10% DC drop standards